Automation of Field Gas Gathering Compressors
A U.S.A. Appalachian natural gas producer was operating three 2-stage Ajax DPC-600 compressors. Suction pressure swings lead to the units shutting down to prevent overloading, thus reducing each unit's run time and requiring personnel to travel out to the remote units to restart them. The operator therefore had been running the units conservatively in order to accommodate the pressure swings without shutting down, however that resulted in less overall production. An engineering study was commissioned to evaluate the compressor configuration to identify the best means for operating each unit via automatic control and unloading to cover the entire operating range. Goals were to keep the engines running safely as field condition changed, and also to increase capacity during normal operation to minimize the number of units that had to be operated at any time. Various alternatives were evaluated including a single 685 in3 (11.2 L) fixed volume pocket; parallel 192 and 383 in3 (3.1 and 6.3 L) fixed volume pockets; parallel 114, 228, and 342 Fig. 36: With only manual control, this 2-stage Ajax compressor was either under-loaded or subject to frequent shutdowns to avoid overload. in3 (1.9, 3.7 and 5.6 L) fixed volume pockets, and an automatic variable volume pocket. In order to evaluate the alternative solutions, performance was compared at more than 1000 operating points within the operating range noted in Figure 37. The highest flow possible at each point was plotted for each case at each condition and the curves were overlayed for comparison. Over the range of 160 to 240 psig (11.0 to 15.5 bar) suction and 900 to 1000 psig (62.1 to 69.0 bar) discharge, the highest average flow was possible with the automatic variable volume pocket, however, the 3-volume pocket (the 2nd from the top surface in Figure 37) provided average flow that was
Ajax DPC-600 Gas compressors ini adalah untuk di jual termasuk dengan spare part 6 ea Piston power P/N YAE - 7516-C-2, Bila anda tertarik silahkan e mail kami di herri_samsuri@pttks.com
A U.S.A. Appalachian natural gas
producer was operating three 2-stage Ajax DPC-600 compressors. Suction pressure swings lead to the units
shutting down to prevent overloading, thus reducing each unit's run time and requiring personnel to travel out to
the remote units to restart them. The operator
therefore had been running the units conservatively
in order to accommodate the pressure swings
without shutting down, however that resulted in less
overall production.
An engineering study was commissioned to
evaluate the compressor configuration to identify the
best means for operating each unit via automatic
control and unloading to cover the entire operating
range. Goals were to keep the engines running
safely as field condition changed, and also to
increase capacity during normal operation to
minimize the number of units that had to be
operated at any time. Various alternatives were
evaluated including a single 685 in3 (11.2 L) fixed
volume pocket; parallel 192 and 383 in3 (3.1 and 6.3
L) fixed volume pockets; parallel 114, 228, and 342
Fig. 36: With only manual control, this 2-stage Ajax compressor was
either under-loaded or subject to frequent shutdowns to avoid overload.
in3 (1.9, 3.7 and 5.6 L) fixed volume pockets, and an automatic variable volume pocket. In order to evaluate the
alternative solutions, performance was compared at more than 1000 operating points within the operating range
noted in Figure 37. The highest flow possible at each point was plotted for each case at each condition and the
curves were overlayed for comparison. Over the range of 160 to 240 psig (11.0 to 15.5 bar) suction and 900 to
1000 psig (62.1 to 69.0 bar) discharge, the highest average flow was possible with the automatic variable volume
pocket, however, the 3-volume pocket (the 2nd from the top surface in Figure 37) provided average flow that was
STOCK SPAREPARTS-OILWELL DRILLING
P/F MUD PUMP IDECO 1000 DUPLEX
1. 50 EA #074802015101 Packing Rod
2. 1 Set #0805-02-0203-00 Packing Set 2-7/8x3-5/8
3. 3 EA #160HB14 Piston Assy 6”
4. 1 EA # 413T, Piston Rod MFK
5. 1 EA # L-308 Gasket Liner
P/F Gardner Denver Duplex Type FXNA/FDFXD Mud Pump
1. 34 EA #25AT37 Gasket Hyd.Ring
2. 8 EA # FX Piston Assy 4-1/2”
3. 20 EA #60AM29 Gasket
4. 12 EA # 114250152 Gasket Liner
5. 20 EA #60BG29 Packing Set
6. 50 EA #60DA120 Gasket Rbr
P/F AJAX TRIPLEX PUMP T150FL
1.4 Set # BM-11333-B-15 PackingWiper
2. 1 EA #P-5185-D Cage Plunger
VARIOUS PARTS
1. 1 EA Cameron Pressure Gauge 5000 PSI
2. 1 EA Bourdon Tube Pressure Gauge 2000 PSI
3. 1 EA Guiberson H Type Oil Saver 3/8-5/8”
4. 1 EA Hercules Cone Stuffing Box 3”X 1-1/4”
5. 2 EA # 6224 Z Bearing SKF
6. 2 EA # 6224 Bearing SKF
7. 1 EA # 6312 Bearing SKF
8. 1 EA # 6312 Z Bearing SKF
9. 1 EA # 6313 Z Bearing SKF
10. 1 EA #6314 Bearing SKF
11. 1 EA #6314 Z Bearing SKF
12. 1 EA #6214 ZZ Bearing Nachi
13. 1 EA #6217 Bearing FAG
14. 1 Set Plidco Skinner 8” Pipe Repair Clamp
15. 1 Set Plidco Skinner 4 “ Pipe Repair Clamp
16. 1 Set Plidco Skinner 3 “ Pipe Repair Clamp
17. 1 Unit RIDGID Model 65R Ratchet Pipe Threader
Silahkan Kontak : herri_samsuri@pttks.com